Jump to main content or area navigation.

Contact Us

Hurricane Sandy Response

Hurricane Sandy Response Efforts

Response timeline | February 20, 2013: 

General

The U.S. Army Corps of Engineers, at the request of New York City, is using two air curtain incinerators at Floyd Bennett Field in Brooklyn, NY to burn vegetative debris, largely from downed trees, gathered in the cleanup from Hurricane Sandy. An air curtain incinerator is a self-contained system that reduces wood debris to ash. It is equipped with air blowers that circulate the air to improve combustion and minimize emissions of fine particles.

The U.S. Environmental Protection Agency has eight fine particle monitors operating around the perimeter of Floyd Bennett Field to monitor for potential impacts of the air curtain devices. An EPA On-Scene Coordinator is on-site while the burning takes place to monitor what is being burned and air quality at the field.

Levels of fine particles are measured by the monitors and averaged over a 24-hour period. Results from the monitors are compared to an established 24-hour health-based standard. That standard is 35 micrograms per cubic meter of air (�g/m3). If the 24-hour standard is exceeded, the EPA will notify the Army Corps and New York City. Monitoring began on December 28.

Air Sampling Results

On November 19, 2012, EPA collected air samples from eight locations around Floyd Bennett Field to measure baseline concentrations of 119 different chemicals including, volatile organic compounds (VOCs), polycyclic aromatic hydrocarbons (PAHs), metals, and dioxin. Exposure to these pollutants can have serious health effects, and in some cases, increase the risk of cancer. During the November 28 pilot burn, and EPA collected air samples from the eight sampling locations for analysis of the same parameters and chemicals. These samples were analyzed in a laboratory.

The baseline and pilot burn results were compared to screening values designed to protect people's health. There were 23 VOCs and one metal (sodium) detected in the baseline results. All the detected concentrations were below levels of concern. During the actual November 28 pilot burn there were 26 VOCs detected. All of the detected concentrations were below levels of concern and similar to the baseline results. There were no PAHs detected in the baseline results or pilot burn results, and no metals were detected in the pilot burn results. Dioxin was not detected in any of the baseline or pilot burn results.

Get the baseline and pilot burn sampling results summary table at https://www.epa.gov/sandy/data/burnsamplingsummary-11-28-2012.pdf

On January 8, 2013, an additional set of air sampling data was collected for VOCs, PAHs, metals, and dioxin. This latest sampling evaluated ongoing air curtain operations. The results from the latest round of air sampling data had 24 VOCs detected and one metal (barium) detected. All concentrations were below levels of concern and similar to the baseline results of November 19 and the pilot burn of November 28. There were no PAHs detected in latest burn results. Dioxin was not detected in the latest burn results.

Get the latest burn sampling results summary table at: https://epa.gov/region02/sandy/data/Pre_and_January_7-8_2013_Summary.pdf

Air Monitoring for Air Curtain Incinerator

Since December 28, results from operating monitors showed that the 24 hour standard has not been violated, except for January 9, 28, 29 and February 5. On those four days, one or more of the EPA's air monitors measured levels that exceeded the 24 hour standard. On all of the four days, overall weather conditions in NYC and most of the northeast and New York City resulted in an inversion in the air, which reduced the atmosphere's ability to mix and dilute pollution. For a more detailed discussion of each day, please see:

Update for January 10 | Update for January 29 | Update for January 30 | Update for February 6

In order to reduce the impacts of the air curtain devices at Floyd Bennett Field on air quality, steps were taken to limit the operation of the devices to reduce particle emissions. On February 14 air curtain incineration ceased.

The EPA has an established Air Quality Index reports daily air quality across the country. The index indicates how clean or polluted the air in a particular area is and what associated health effec ts might be a concern. For more information about the Air Quality Index, visit http://airnow.gov/.

Historical Results of EPA's air monitoring and the locations of the monitors can be found at:
https://www.epa.gov/sandy/data/fbf-results.pdf and
https://www.epa.gov/sandy/pdf/fbf-map.pdf

The image below showed the location of the eight monitors, on Floyd Bennet Field, New York City, surrounding the air curtain burn device.

aerial image of Floyd Bennett Field, New York City showing air monitor locations on a runway surrounding the air curtain burn device FBF-05 FBF-06 FBF-08 FBF-04

Top of page

Historical Information About the Response

Response Timeline

Nov 2012  8   9  10 11 12 13 14 15 16 17 18 19 20 21 23 24 25 26 27 28 29 30
Dec 2012  1   2   4   6   8  10 12 14 17 18 27
Jan 2013  2   3   4   7   8   9  10 11 14 15 16 17 18 22 23 24 25 29 30 31
Feb 2013  1   4   5   6  7 8 12 13 14 20 21
March 2013  1   7 
April 2013 11

 

Jump to main content.