THE ENVIRONMENTAL TECHNOLOGY VERIFICATION
                                     PROGRAM
                                   ET
AM   r\
    U.S. Environmental Protection Agency                                               NSF International
                     ETV Joint Verification Statement
    TECHNOLOGY TYPE:   COAGUALTION AND MEMBRANE FILTRATION USED IN
                           DRINKING WATER TREATMENT SYSTEMS
    APPLICATION:         REMOVAL OF ARSENIC IN DRINKING WATER
    TECHNOLOGY NAME:  MICROZA® MICROFILTRATION SYSTEM

    COMPANY:            PALL CORPORATION
    ADDRESS:             2200 NORTHERN BLVD           PHONE:  (516)484-5400
                           EAST HILLS, NEW YORK 11548   FAX:     (516)484-3548
    WEB SITE:             www.PALL.com
    EMAIL:                william_sellerberg@pall.com
The U.S. Environmental Protection Agency (EPA) supports the Environmental Technology Verification
(ETV)  Program to facilitate the  deployment of innovative or improved environmental technologies
through performance verification and dissemination of information. The goal of the ETV Program is to
further environmental protection by accelerating the acceptance and use of improved and more  cost-
effective technologies. ETV seeks to achieve this goal by providing high-quality, peer-reviewed data on
technology performance to those involved in the design, distribution, permitting, purchase, and use of
environmental technologies.

ETV works in partnership with  recognized standards  and  testing organizations, stakeholder  groups
(consisting of buyers, vendor organizations, and permitters), and with the full participation of individual
technology developers.  The program evaluates the performance of innovative technologies by developing
test plans that  are responsive to the needs of stakeholders, conducting field or laboratory tests (as
appropriate),  collecting  and analyzing data, and preparing peer-reviewed reports.  All evaluations are
conducted in accordance with rigorous  quality assurance protocols to  ensure that data of known and
adequate quality are generated and that the results are defensible.

NSF International (NSF) in cooperation with the EPA operates the Drinking Water Systems (DWS)
Center, one of six technology areas under the ETV Program. The DWS  Center recently evaluated the
performance  of a membrane filtration  system  for the reduction  of arsenic in drinking water.  This
verification  statement provides  a summary of the test  results for the Pall Corporation Microza®
Microfiltration System. The NSF Drinking Water Systems Laboratory performed the verification testing.
The verification report contains a comprehensive description of the complete verification test.
05/17/EPADWCTR    The accompanying notice is an integral part of this verification statement.          September 2005
                                       VS-i

-------
ABSTRACT
Verification testing of the Pall Corporation Microza® Microfiltration System for arsenic removal was
conducted at the Oakland County Drain Commissioner (OCDC) Plum Creek Development well station
located in Oakland County, Michigan from August 19 through October 8, 2004.  The source water was
groundwater from the two supply wells and the raw water for the verification test was withdrawn from the
pressure tank at the site. Verification testing was conducted at the operating  conditions specified by the
manufacturer.  The raw water, with a pH in the range of 7.0 to 7.4, was treated with sulfuric acid to lower
the pHto a range of 6.6 to 7.0. Chlorine (bleach) was added to oxidize arsenic  (III) to arsenic (V) and iron
was added to coagulate the arsenic. When operated under the manufacturer's  specified conditions at this
site,  with a flow  rate of 6.3 gallons per minute  (gpm), the Microza System reduced the total arsenic
concentration from an average of 13 (ig/L in the feed water (raw water after chemical addition) to below
the detection limit of 2 (ig/L in the filtrate (treated) water.

TECHNOLOGY DESCRIPTION
The following technology description was provided by the manufacturer and has not been verified.

The Pall process is based on chemical coagulation, mixing, and microfiltration with no intermediate solids
separation process. The Microza System includes pretreatment with sodium hypochlorite to oxidize any
arsenic (III) to arsenic (V), and iron present in the water supply. Ferric chloride is added to augment any
naturally occurring iron and optimize the iron dose. Sulfuric acid is added to  adjust the pH to  an optimal
level, as determined during shakedown testing at the site.  This  chemically treated water (feed water)
enters the feed tank supplied as part of the system. The coagulated water in the feed tank is mixed for five
minutes and pumped directly to the microfiltration module. Flow enters the module on the outside of the
membrane, passes through the  membrane, and flows on the inside of the membrane to the outlet of the
module. The microfiltration membrane filters the  water, removing the precipitate, including arsenic, iron,
and any other precipitated constituents. A portion of the  filtrate is collected  in a tank (reverse filtration
tank) for use during the backwash process. The microfiltration system is designed to filter all of the water
under normal operating conditions [i.e., there is no reject (concentrate) water from the system].

The  Microza System uses a combination of air and water to backwash  the microfiltration membrane.
Water is supplied from the reverse filtration tank  (30 gallon tank), which holds filtrate from the system.
A compressor with a fully automated control system supplies air for the air scrub. When a backwash is
initiated, the air system is activated and supplies air to the feed side of the module. The reverse filtration
pump drives filtrate in a reverse flow through the membrane. The combination of air scrubbing and
reverse  water flow  removes  the  particles that  have been  trapped by the microfiltration module.
Occasionally, microfiltration membranes require chemical cleaning to  remove  materials  that are not
removed during the backwash process.  Chemical clean in place (CIP) is typically required on a two or
three month basis.

VERIFICATION TESTING DESCRIPTION
Test Site
The verification testing site was OCDC Plum Creek Subdivision well site in Oakland, Michigan.  The
source water was groundwater from two wells located at this site. The  two wells pumped  water to a
common pressure tank that served as the raw water supply to the Microza System. Water quality data
from historical information and from the characterization test showed the  wells had similar water quality.
Total arsenic ranged from 9 to 14 (ig/L and total iron ranged from  0.9 to 1.0 mg/L. The pH was steady in
the 7.0 to 7.6 range with alkalinity of 240 to 290 mg/L as CaCO3.  Raw water turbidity from the pressure
tank was typically in the 3.3 to 8.4 Nephelometric  turbidity units (NTU) range.
05/17/EPADWCTR    The accompanying notice is an integral part of this verification statement.           September 2005
                                          vs-ii

-------
Methods and Procedures

Operations, sampling, and analyses were performed in accordance with the Product Specific Test Plan
(PSTP) developed and approved for this verification test. The PSTP included a Quality Assurance Project
Plan (QAPP) designed to assure the quality of the data collected and to provide an accurate evaluation of
the treatment system under the field conditions. Testing included characterization of the raw water,  an
arsenic loss test (no chemical fed to the system), and a 30-day verification test.

The verification test was performed from September 9, 2004 through October 8,  2004.  The Microza
System was operated continuously for the 30-day verification test, independent of the well operations, by
using water  supplied from the well station's pressurized supply tank. Flow rate(s),  production volume,
water temperature, and system pressure(s) were monitored and recorded daily. These data provided the
basis for calculating transmembrane pressure and flux through the membrane system. Raw, feed (after
sulfuric acid, chlorine, and iron addition), and filtrate (treated) water samples were analyzed on-site for
pH, temperature, turbidity,  free and total residual chlorine,  color, and dissolved oxygen by the field
operator. Grab samples were collected and delivered to the NSF Chemistry Laboratory to be analyzed for
alkalinity, calcium, magnesium, iron,  manganese,  sulfate, chloride, total organic carbon (TOC), total
suspended solids (TSS), and fluoride.  Samples for total arsenic were collected three times per week, plus
11  samples were collected  during  a 58-hour intensive  sampling period. In addition to the 23 sets  of
samples  for total arsenic, a total of eight  sets of arsenic samples were  speciated during  the test  to
determine the  soluble arsenic concentration and the concentrations of arsenic (III)  and  the arsenic (V)
present in the  soluble fraction.  Samples  of backwash water were collected and analyzed in addition to
monitoring backwash and chemical cleaning operating parameters.

Complete descriptions of the  verification testing results and quality assurance/quality control (QA/QC)
procedures are included in the verification report.

VERIFICATION OF PERFORMANCE
System Operation
Pall performed the system  startup and  shakedown  testing,  which included a system integrity  test,
optimization of the chemical feed rates, and determination of backwash frequency. The verification test
was conducted under the manufacturer's specified operating conditions. Chemical feeds were established
to feed 1.0 mg/L of total chlorine to maintain total residual chlorine in the feed water of 0.5 to 1.0 mg/L.
The ferric chloride feed rate was set to deliver 3 mg/1 of ferric chloride (1 mg/L as  Fe) and the sulfuric
acid feed system was set to maintain a pH of 6.8 in the feed water. The flow rate for filtrate was set at 6.3
gpm to give a targeted flux rate of 120 gallons per day per square foot (gfd). The backwash system was
set to  backwash the membrane every 30 minutes. The backwash cycle time was  about two minutes,
including a one-minute air  scrub period, followed  by a 30-second  forward flush period. All operating
conditions remained steady throughout the verification test.

System pressure was monitored at three locations, feed water (inlet to the membranes), filtrate (exit of the
membranes),  and on the  concentrate side of the membrane unit. The pressure on  the feed water line
slowly, steadily increased over the 30-day period, while the filtrate pressure remained steady, as expected.
The transmembrane pressure (TMP) steadily increased  indicating  the membranes  were accumulating
materials in the pores that were not removed by the backwash.  Pall recommends that the Microza System
be cleaned using the CIP procedure when TMP exceeds 35 pounds per square inch (psi). After 30 days of
operation, the  TMP was 15.5  psi, indicating that cleaning was not yet required. However, in  accordance
with PSTP, the membranes were chemically cleaned  and checked for performance after cleaning at the
end of the test period.
05/17/EPADWCTR    The accompanying notice is an integral part of this verification statement.          September 2005
                                          vs-iii

-------
The  hydraulic  flow conditions  for membrane systems, such  as  the  Microza  System, are typically
described by calculating the flux, the temperature corrected flux (20°C), and the specific flux at 20°C. The
flux remained constant throughout the test. Specific flux started at 17.2 gfd/psi and decreased to a low of
9.1 gfd/psi near the end of the 30-day test. TMP increased from 8.1  psi to 15.7 psi over the same period.
The steady rise in TMP can be used to project when the TMP would reach 35 psi, the Pall-recommended
TMP when chemical cleaning is required. It is projected that the  TMP would approach 35 psi at between
90 and 120 days. Thus, it could be  expected that the membranes would require chemical cleaning in this
site application about once every 90 and 120 days, as well.

Water Quality Results
The results of total arsenic analyses are shown in Figure VS-1. The raw water total arsenic averaged 11
ug/L  with dissolved arsenic of 11 ug/L. Arsenic  (III) was the  dominant  species in the raw water,
averaging 10 ug/L. The feed water (after chemical treatment) total arsenic  concentration averaged  13
ug/L, with <2 ug/L in the soluble state. Pretreatment completely converted the raw water arsenic (III) to
the arsenic (V) species. The filtrate water total arsenic concentration was below the detection limit of 2
ug/L in all samples collected during the verification test.
£ 18 n
3. 16-
n 14 -
1 1^
* 5:
i 2
£ 0 -

	 ^ j .- I^.._:I:4
"''" !»».»'•--*•


\V \V ^\V yl\V \V \V \V ^ \V yl\V \V \V \r S \V yl\V
Date
--+-- Total Arsenic-Raw • ••• • Total Arsenic-Feed — * — Total Arsenic-Filtrate
(ug/L) (ug/L) (ug/L)

Note: Arsenic Intensive Sampling Test occurred on 9/20/04.
Figure VS-1.  Total Arsenic Results

The addition of sulfuric acid to the raw water reduced the pH from 7.0 to 7.6 to a range of 6.6 to 7.0 in the
feed water. The acid addition reduced the alkalinity of the water from an average of 250 mg/L as CaCO3
in the raw water to 230 mg/L as CaCO3 in the feed water. The filtrate alkalinity averaged 230 mg/L as
CaCO3, indicating that the  membrane had no impact on the alkalinity concentration. The average raw
water iron concentration was 0.99 mg/L, and the feed water averaged 2.3 mg/L of iron after the addition
of ferric chloride. The filtrate water iron concentration was <0.02 mg/L in all but two samples. One day
the iron concentration was 0.10 mg/L and the other sample showed 3.6 mg/L, which appear to be outliers.
Turbidity was  also reduced  through the Microza System from an average bench-top turbidity of 4.9 NTU
in the raw water to an average in-line turbidity  of <0.05 NTU in the filtrate water.

The  backwash water was  sampled on five  occasions and  found to have  an  average total  arsenic
concentration of 580 (ig/L, an average iron concentration of 114 mg/L, and an average TSS concentration
05/17/EPADWCTR
The accompanying notice is an integral part of this verification statement.
                       vs-iv
September 2005

-------
of 290 mg/L.  The backwash cycle occurred every 30 minutes and yielded an average of two gallons of
backwash water per cycle or 96 gallons per day. This represented 1.2% of the average daily treated water
production. The backwash water was enriched in arsenic, iron, and TSS, as would be expected given the
removal of arsenic and iron as measured in the filtrate. Local disposal requirements determine whether
this water is acceptable for discharge to  a sanitary sewer system, some other discharge location,  or if it
will require further treatment prior to discharge. The backwash water is not considered a hazardous waste
based on the arsenic concentration, which is below the 5,000 (ig/L (5.0 mg/L) limit under the Resource
Conservation and Recovery Act (RCRA).

Operation and Maintenance Results
The Microza System was found to be easy to operate and required little time for daily maintenance. The
field staff was  on-site for two to three hours per day. Most of the time on-site was  spent performing field
activities, including daily  chemical  analyses, flow checks, calibrations, etc. In a  normal operation,  the
inline pH meters and turbidimeters would be used for system checks. The Microza System has a PLC/PC
that records data for all key operating parameters, including flow data, pressure information, backwash
cycles, etc. The system also has manual readouts on the feed and filtrate flow rate,  the pressures for feed,
filtrate and concentrate, and on the  inline pH meters  and turbidimeters. It is estimated that the time to
check the system  on-site  would  be minimal, possibly  less than 30 minutes, except when chemical
feedstocks needed to be replenished or inline instruments calibrated.  The PLC can be setup for  remote
access so that main system parameters can be monitored without a site visit.

The chemical feed system maintained steady chemical feed rates over the duration of the test. The only
maintenance performed on the Microza System was the replacement of one pH  meter cable that failed on
September 25.  The cable was shipped to  the site and the field personnel were able to install the cable and
recalibrate the pH meter.

The  Pall operation and maintenance (O&M)  manual provides a  detailed  description of the  system,
appropriate safety precautions, and detailed descriptions of operating procedures, capability and operation
of the computer control system, and  specific instructions for utility operators. The maintenance section of
the manual includes descriptions  of components that require maintenance.   Maintenance checklists,
including example  forms  for  daily and periodic maintenance activities,  are included along  with a
troubleshooting section in a tabular format. The review of the O&M manual shows that the manual is well
organized and easy to read.

Consumables and Membrane Chemical  Cleaning

The Microza System used a 6% sodium hypochlorite (bleach) as the stock chemical for adding chlorine to
the system. A total of 3.9 gallons of 6%  bleach solution was used to treat 252,600 gallons of raw water.
This equates to an average concentration  added to the raw water of 0.92 mg/L. Iron was added to the raw
water using a 40% ferric chloride solution. A total of 1.3 gallons (15.2 pounds)  of ferric chloride solution
was used to treat 252,600 gallons of raw  water. Sulfuric acid addition was based on the need to lower pH
to an operating range of 6.6 to 7.0. Approximately 5.4 gallons of sulfuric acid was used over the  30-day
test to treat 252,600 gallons of raw water.

The  chemical  CIP procedure used  by Pall to clean membranes uses a sodium  hydroxide and  bleach
solution that is recirculated through the system for two hours. After a rinse, a citric acid solution is used to
further clean the membranes with low pH water, followed by a rinse. Pall performed a CIP before the start
of the verification test and again at the end of the test. Field staff observed both cleaning procedures and
recorded the chemical use  and TMPs before and after the final  cleaning.  The CIP procedure took  around
five hours to complete.  This time includes the time to drain the feed water tank, make the chemicals used
for cleaning, perform the entire procedure, and reset the unit for operation. The chemicals used  for the
05/17/EPADWCTR    The accompanying notice is an integral part of this verification statement.           September 2005
                                          VS-V

-------
post verification test CIP included: 1.25 Ibs. of sodium hydroxide  (NaOH),  942 mL of bleach (6%
solution), and 1.688 Ibs of citric acid. The cleaning solutions were made by diluting the sodium hydroxide
and bleach into  15 gallons of water, and the citric acid was diluted into 10 gallons of water.  At the end of
the CIP, the TMP had returned to the original TMP at the beginning of the verification test. These data
indicated that the unit was cleaned and restored to original operating  condition. The final check was an
integrity test, which demonstrated that the membranes were still in good condition.

Electrical power consumption was estimated based on pump, mixer, and air compressor horsepower of
2.75 hp-hr.  With  miscellaneous  electrical use by  chemical  feed  pumps  and  the  PLC/PC,  power
consumption is estimated to be 2.55 kilowatt-hr.

Quality Assurance/Quality Control

NSF provided technical and QA  oversight of the verification testing as  described in the verification
report, including an audit of nearly 100% of the data. The NSF QA department conducted a technical
systems audit during testing to ensure the testing was in compliance with the test plan and performed a
QA review of the analytical data.  A complete description of the QA/QC procedures is provided in the
verification report.
     Original Signed by
     Sally Gutierrez
                  10/3/05
    Sally Gutierrez                     Date
    Director
    National Risk Management Research Laboratory
    Office of Research and Development
    United States Environmental Protection Agency
Original Signed by
Robert Ferguson
10/5/05
                                       Robert Ferguson
                                       Vice President
                                       Water Systems
                                       NSF International
                           Date
    NOTICE:  Verifications are based on an evaluation of technology performance under specific,
    predetermined criteria and the appropriate quality assurance procedures.  EPA and NSF make no
    expressed or implied warranties as to the performance of the technology and do not certify that a
    technology will always operate as verified.  The end-user is solely responsible for complying with
    any and all applicable federal, state, and local requirements.  Mention of corporate names, trade
    names, or commercial products does not constitute endorsement or recommendation for use of
    specific products.  This report is not an NSF Certification  of the specific product mentioned
    herein.
       Availability of Supporting Documents
       Copies  of the ETV Protocol for Equipment Verification  Testing for Arsenic Removal
       dated April 2002, the  verification statement, and the verification report (NSF Report
       #04/10/EPADWCTR) are available from the following sources:
       (NOTE: Appendices are not included in the verification report. Appendices are available
       from NSF upon request.)

       1.  ETV Drinking Water Systems Center Manager (order hard copy)
           NSF International
           P.O. Box 130140
           Ann Arbor, Michigan 48113-0140
       2.  NSF web site: http://www.nsf.org/etv (electronic copy)
       3.  EPA web site: https://www.epa.gov/etv (electronic copy)
05/17/EPADWCTR
The accompanying notice is an integral part of this verification statement.
                       vs-vi